Megger LTW315 Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire, 3 Wire 440V
- RS-stocknr.:
- 237-899
- Fabrikantnummer:
- LTW315
- Fabrikant:
- Megger
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 618,00
(excl. BTW)
€ 747,78
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Op voorraad
- Plus verzending 21 stuk(s) vanaf 11 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 618,00 |
*prijsindicatie
- RS-stocknr.:
- 237-899
- Fabrikantnummer:
- LTW315
- Fabrikant:
- Megger
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Megger | |
| Loop Impedance Test Type | 2 Wire, 3 Wire | |
| Maximum Voltage Measurement | 440V | |
| Calibrated | UKAS | |
| Best Loop Test Accuracy | ±10% | |
| Non-Trip Loop Test | Yes | |
| Safety Category | CAT IV 300 V, IEC 61010 | |
| Display Type | LCD | |
| Battery Type | AA | |
| Battery Life | 2000 Tests | |
| Power Source | Battery | |
| Dimensions | 203 x 148 x 78mm | |
| Weight | 1kg | |
| Height | 78mm | |
| Model Number p | LTW315 | |
| Maximum Operating Temperature | +50°C | |
| Length | 203mm | |
| Safety Category Level | CAT IV | |
| Safety Category Voltage | 300V | |
| Minimum Operating Temperature | -10°C | |
| Width | 148mm | |
| Alles selecteren | ||
|---|---|---|
Merk Megger | ||
Loop Impedance Test Type 2 Wire, 3 Wire | ||
Maximum Voltage Measurement 440V | ||
Calibrated UKAS | ||
Best Loop Test Accuracy ±10% | ||
Non-Trip Loop Test Yes | ||
Safety Category CAT IV 300 V, IEC 61010 | ||
Display Type LCD | ||
Battery Type AA | ||
Battery Life 2000 Tests | ||
Power Source Battery | ||
Dimensions 203 x 148 x 78mm | ||
Weight 1kg | ||
Height 78mm | ||
Model Number p LTW315 | ||
Maximum Operating Temperature +50°C | ||
Length 203mm | ||
Safety Category Level CAT IV | ||
Safety Category Voltage 300V | ||
Minimum Operating Temperature -10°C | ||
Width 148mm | ||
N.v.t.
- Land van herkomst:
- GB
Megger Loop Impedance Tester
The Megger earth loop impedance testers are 2-wire, 440V and ±10% test loop accuracy. This tester is to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy but do not trip 30mA RCDs and can be used on a wide range of voltages. A loop test is performed with only 2 test leads. This can be either phase to earth, phase to neutral and phase to phase.
Supplied with
Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.
Supplied with
Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.
Features and Benefits
Backlit display
0.01Ω resolution
No-trip loop test on circuits with RCDs of ≥30 mA
3-phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available.
10second non-trip loop test time with autotest extension up to a further 10seconds
if noise is detected, to improve the accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected
0.01Ω resolution
No-trip loop test on circuits with RCDs of ≥30 mA
3-phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available.
10second non-trip loop test time with autotest extension up to a further 10seconds
if noise is detected, to improve the accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected
no need to press the test button means much safer testing
PFC display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding.
Optional 10A fused 2 wired test leads and crocodile clip set
PFC display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding.
Optional 10A fused 2 wired test leads and crocodile clip set
Certifications
EN61557
EN61010-1
EN61010
IEC61010-1 300V CATIV
EN61010-1
EN61010
IEC61010-1 300V CATIV
